JIC fittings are compression fittings that have parallel threads and a 37-degree flare seating surface, as specified by SAE J514 and ISO 8434-2. The JIC 37-degree fittings are compatible with SAE 37 fittings, making them easily interchangeable. 37-degree fittings are used in higher pressure applications. Comparatively, the SAE 45-degree fittings are used for low pressures, such as automotive, air conditioning and refrigeration.
The most common materials for JIC 37 hydraulic fittings are carbon steel and stainless steel. Their parallel threads seal on a metal-to-metal surface, and the flared tube surface can be reliably sealed and re-sealed, making field replacement easy.
JIC is available in sizes ranging from -02 up to -40. A dash size is the determination for tube, hose and fitting measurements, measured in 1/16-inch increments. For instance, a -04 = a 4/16 or ¼ inch ID hose and a -32 = 32/16 or 2-inch ID hose.
Suggested JIC 37 Degree Fitting Assembly Instructions
Wet Torquing
Wet torquing means lubricating the threads and O-ring (if applicable) of the fitting with hydraulic fluid before installation. However, the coefficient of friction can significantly vary due to differences in material, thickness, thread quality or plating types of different components.
Lubrication produces a more consistent coefficient of friction, increasing the clamping force on the sealing area and reducing the torque on threads. Over-tightening the connection causes threads to deform and lose their ability to sustain a sufficient clamping force on the seating surface. Severe conditions and/or prolonged operation can produce yielding that is likely to cause leaks. Wet torquing threads and O-rings (if applicable) is always recommended to maintain the quality and consistency of the connections.
Alternative Assembly Technique
If for any reason the torque method is not possible, you should still follow steps 1 through 3 above, then take these steps:
Note: Though following the steps above is a good rule of thumb, the required rotation typically decreases as the fitting size increases.
Torque Values for JIC 37 Degree Fittings
Over-tightening is likely the most common cause of a leaking JIC fitting. When over tightening, the mating seals bind to each other resulting in the leak. Follow these three steps to properly tighten and torque down JIC 37 fittings to avoid leaks: